Many data ceters are nowadays focusing on high performance computing applications, when doing so, heat loads per cabinet are expected to dramatically increase compared to the tradional, more contained, loads. This is not only already a challenge for new deployments, but can become an extreme hurldle for existing ones that are shifting towards these applications, while the cooling infrastructure is already in place.
ColdLogik Rear Door Coolers enhance the efficiency of most data centers without the need for any changes to their current design. By negating the heat at source, and removing the need for air mixing or containment, you gain the ability to significantly increase the supply water temperature, which means more efficient external heat rejection options become available.
In some scenarios this means that the ColdLogik RDC solution removed all compressor-based cooling therefore promoting the option to free cool all year round.
PURPOSE-BUILT FOR 48VDC ENVIRONMENTS
Engineered to integrate with OCP ORV3 architectures and 48VDC busbar power distribution
DESIGNED FOR HYBRID COOLING ARCHITECTURES
Complements direct-to-chip cooling by managing remaining air-side heat at the rack level
FUTURE-READY FOR HIGH-DENSITY RACKS
Built to support next-generation AI and HPC deployments within OCP-aligned infrastructures
COOLING WITHOUT TOUCHING YOUR POWER SETUP
Operates alongside existing 48VDC architectures without impacting power topology
OCP Hardware For High-Performance Workloads
Discover our OCP ORv3–compliant rack and power architecture designed for high-density AI and HPC deployments, with AC and DC power support beyond 100 kW per rack.
Active Rear Door Cooler (RDHX)
CL20 Active
Up to 92kW sensible cooling
42U, 48U and 52U
600w, 750w and 800w
CL23 HPC Active
Up to 200kW sensible cooling
Actual headroom 220 kW+
48U and 52U
800w
Legacy Data Centers
There are many reasons to get more from an existing data center: increasing revenue streams, removing hot spots, offering customers greater flexibility, or extending the data center lifecycle. ColdLogik RDC provides a fully retrofittable solution for legacy data centers.
It can be fitted to any OEM rack, use return water from existing perimeter cooling and chiller systems, and be top- or bottom-fed as standard. It does not affect adjacent bayed racks, preserves full rear rack access, and can be retrofitted into hot aisle containment without changing the floor layout.
Energy and Water savings
The ColdLogik RDC solution can dramatically change the efficiencies of data center environments. From year-round free cooling ability, which can cut energy consumption from cooling in the data center by over 90%. Through to higher water temperatures, in a closed loop system, which can save monumental volumes of water that can then be deployed in communities that need the resource more. The ColdLogik cooling system truly encapsulates the next step in site wide efficiency gains.
Make the Best out of your Real State
Thanks to the space saved in not using containment, CRAC units and related infrastructure, up to a 60% of the space previously reserved for those elements now becomes available again, which can be used for future expansions or used in a different way
Reach out to us for a discussion on your cooling challenges
×
Thank you. Check your email for details on your request.
Please allow a minute for the confirmation to arrive in your email.
Canada
Latin America (English)
Latin America (Espanol)
USA
China
India
Japan
Republic of Korea
South East Asia (English)
Austria
Belgium
France
Germany
Italy
Netherlands
Spain
Switzerland
Turkey
UK
Africa (english)
Africa (français)
Middle East (english)
Australia
New Zealand