EMDX3 modular measuring unit 4 module A 230V 5A 500V RS485+IMP measurement of current voltage frequency active and reactive apparent power and power factor
| Pole type | Three conductor/four conductor |
|---|---|
| Connectable conductor cross section solid-core (Min-Max) | 2.5 - 4 mm² |
| Mounting method | DIN rail |
| Ampere meter | Yes |
| Reactive power meter | Yes |
| With rotational speed meter | No |
| Frequency meter | Yes |
| Pulse counter | No |
| Voltmeter | Yes |
| Harmonics measurement | No |
| Apparent power | Yes |
| Effective power measurement device | Yes |
| Power factor | Yes |
| Step angle (cos phi) | No |
| Measured value memory | Yes |
| Measurement type load profile | No |
| Calibrated | Yes |
| Accuracy class active energy according to IEC 62053-22 | Other |
| Accuracy class reactive energy according to IEC 62053-23 | Other |
| Pulse output | Electrical |
| Number of voltage measurement inputs | 3 |
| Number of current measurement inputs | 3 |
| Voltage type (supply voltage) | AC |
| Supply voltage AC 50 Hz (Min-Max) | 100-240 V |
| Supply voltage AC 60 Hz (Min-Max) | 100-240 V |
| Measuring range for frequency (Min-Max) | 45-65 Hz |
| Nominal current (In) | 5 A |
| Max. current (Imax) | 6 A |
| Display | LCD |
| Remote display | No |
| Suitable for RJ plug | No |
| Supporting protocol for IEC 61850 Ethernet | No |
| With communication interface KNX | No |
| Wth communication interface M-Bus | No |
| With communication interface RS-485 | Yes |
| Supporting protocol for OPC UA PubSub | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for Modbus | Yes |
|---|---|
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for other bus systems | No |
| With audit logging (audit log) | No |
| With firmware signature | No |
| With logging of security events (security event log) | No |
| With Role Based Access Control (RBAC) | No |
| Web server with HTTPS transfer protocol | No |
| Width | 71.2 mm |
| Height | 90 mm |
| Depth | 65 mm |
| Degree of protection (IP), front side | Other |
| Degree of protection (IP) | IP54 |
| Operating / setting temperature (Min-Max) | -5-55 °C |
| Storage temperature (Min-Max) | -25-70 °C |
| Nominal voltage (Min-Max) | 0-230 V |
| Frequency (Min-Max) | 50-60 Hz |
| Terminal marking indication | Yes |
| Connection type | Screwed terminal |
| Contains Batteries and/or Accumulator | No |
| Battery ou Accumulator (Pack1) | Not applicable |
| Element Composition (Pack1) | Not applicable |
| Number of Pack 1 | 1 |
| Number of Single Element (Pack1) | 1 |
| Single Element weight (Pack1) | 250 g |
| Pack1 Location | Single element |
| Regulation Type (Pack1) | I : Industrial (not Portable) |
| Battery ou Accumulator (Pack2) | Not applicable |
| Element Composition (Pack2) | Not applicable |
| Connected object | No |
| Programming way | Not applicable |
| With voice command | No |
| Programmable | Yes |
| Interoperable connection Protocol | No |
| Connectable by Internet box | No |
| Product use function | Energy distribution |