| Scope of delivery of the one-way system | Transmitter and receiver |
|---|---|
| Max. opening angle | 0.5 ° |
| Pre failure notice | No |
| With time function | No |
| Rated switching distance | 6 mm |
| Max. switching distance | 7 mm |
| Max. output current | 3 mA |
| With reflector | Yes |
| Analogue output 0 V ... 10 V | No |
| Analogue output 0 mA ... 20 mA | No |
| Analogue output 4 mA ... 20 mA | No |
| Analogue output -10 V ... +10 V | No |
| With other analogue output | No |
| Setting procedure | Manual adjustment |
| With communication interface analogue | No |
| With communication interface AS-Interface | No |
| With communication interface CANOpen | No |
| With communication interface DeviceNet | No |
| With communication interface Ethernet | No |
| With communication interface INTERBUS | No |
| With communication interface PROFIBUS | No |
| With communication interface RS-232 | No |
| With communication interface RS-422 | No |
| With communication interface RS-485 | No |
| With communication interface SSD | No |
| With communication interface SSI | No |
| Number of semiconductor outputs with signalling function | 0 |
| Number of contact energized outputs with signalling function | 1 |
| Number of protected semiconductor outputs | 0 |
| Number of protected contact energized outputs | 1 |
| Type of interface for safety communication | Other |
| Type of electric connection | Clamp |
|---|---|
| Type of switching output | Relay contact |
| Type of switch function | Change-over contact (NO/NC) |
| Operation agent-safety class | Safety class 2 |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| Construction type housing | Other |
| Width sensor | 16 mm |
| Height of sensor | 65 mm |
| Length of sensor | 112 mm |
| Material of optical surface | Plastic |
| Housing material | Plastic |
| Max. output current at protected output | 3 mA |
| Min. reflector distance | 0.2 mm |
| Ambient temperature | -10-55 °C |
| Switching frequency | 60 Hz |
| Rated control supply voltage AC 50 Hz | 24-253 V |
| Rated control supply voltage AC 60 Hz | 24-253 V |
| Rated control supply voltage DC | 12-24 V |
| Voltage type | AC/DC |
| With monitoring function downstream switching devices | No |
| Laser protection class | None |
| Type of light | Infrared light |
| Light dot | 0 mm² |
| Material of cable sheath | Other |
| With restart blockage | No |
| Suitable for safety functions | No |
| Degree of protection (IP) | IP67 |
| Operating / setting temperature | -10-55 °C |
| Storage temperature | -10-55 °C |