  1. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 0.43 mH - I RMS 161.6 A
  2. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 0.45 mH - I RMS 150 A
  3. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 0.48 mH - I RMS 123 A
  4. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 0.58 mH - I RMS 121.2 A
  5. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 0.72 mH - I RMS 83 A
  6. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 0.86 mH - I RMS 80.8 A
  7. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 0.90 mH - I RMS 75 A
  8. Detuned reactor three-phase 50 Hz tuning frequency 135Hz for three-phase capacitors - Ln 1 mH - I RMS 125.6 A
  9. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for 3 single-phase capacitors - Ln 1.34 mH - I RMS 87 A
  10. Detuned reactor three-phase 50 Hz tuning frequency 135Hz for three-phase capacitors - Ln 1.35 mH - I RMS 94.2 A
  11. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for 3 single-phase capacitors - Ln 1.44 mH - I RMS 74.4 A
  12. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 1.45 mH - I RMS 42 A
  13. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 1.73 mH - I RMS 40.4 A
  14. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 1.78 mH - I RMS 38 A
  15. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for 3 single-phase capacitors - Ln 10.70 mH - I RMS 12 A
  16. Detuned reactor three-phase 50 Hz tuning frequency 135Hz for 3 single-phase capacitors - Ln 14.1 mH - I RMS 16 A
  17. Detuned reactor three-phase 50 Hz tuning frequency 135Hz for three-phase capacitors - Ln 2.02 mH - I RMS 62.8 A
  18. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for 3 single-phase capacitors - Ln 2.15 mH - I RMS 50 A
  19. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for 3 single-phase capacitors - Ln 2.68 mH - I RMS 44 A
  20. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 2.85 mH - I RMS 21 A
  21. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 3.45 mH - I RMS 20.2 A
  22. Detuned reactor three-phase 50 Hz tuning frequency 135Hz for 3 single-phase capacitors - Ln 3.52 mH - I RMS 62 A
  23. Detuned reactor three-phase 50 Hz tuning frequency 135Hz for three-phase capacitors - Ln 4.05 mH - I RMS 28.9 A
  24. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for 3 single-phase capacitors - Ln 4.30 mH - I RMS 25.1 A
  25. Detuned reactor three-phase 50 Hz tuning frequency 189Hz for three-phase capacitors - Ln 4.31 mH - I RMS 16.2 A